RESISTANCE OF IMPACT AT LOW TEMPERATURE
When tested in accordance with DIN EN 477 and BS-7413:1991 Appendix G,no sample exhibits cracking through the entire profile wall thickness.
PERFORMANCE
When tested in accordance with DIN 18055 & BS-6375 PART 1.1989.Test RIG.DIN EN 107.preliminary.Fixed lights air leakage less than 1.0m3/m/hr at an air pressure of 600Pa. Opening lights less than 6.5m3/m/hr at an air pressure of 600 Pa.No damage after a wind gust test at an applied pressure of 2400Pa.Actual performance achieved will depend on frame size and style
DESIGN
All main profile are multi-chambered with reinforcement carried in sealed cavities as required.Glazing and casement rebates are drained.
Glazing gaskets and weather seals are retained in purpose design grooves.Glazing gasket in butt-joint at the heads.
Glazing beads are either hollow construction with purpose designed groove for glazing gasket,or co-extruded beads with an integral gasket.External beads feature a continuous "snap-in" hook providing a secure externally glazed system.Alternatively,window can be manufactured as an internally glazed system using standard beads.
The main U-PVC profiles shall be multi-chambered ,three chamber back to front and a minimum 58mm dip. The center chamber being for reinforcement shall be fully sealed at welded joints.The profile shall have a soft line design with slopping rebats and nicely rubbed edges.The system incorporates frames,mullions,movable mullions,sashes and special profiles for certain window operation.Different profile series for various applications are included in the system.
|